Low Voltage Back
 

 

 

 

 
 
Home  >> Products >> Low Voltage >> Relay & Timer >> Linear Control Solid State Relay
 

 

 

 
1. Application

  • High rellability by S.M.T & TQC.(Surface Mounting Technology)
  • High Isolation over than 50MQ/500VDC
  • High dielectric over than 2.5KV
  • Low enable current less than 7.5mA/12VDC CMOSIC or TTL Compatible.
  • Low EMI/EFI& surge by Zeero cross Trigger Method.
  • High surge current duration,over 10 Times of rated current/one cycle.
  • High surge voltage duration by snubber circuit
 

2. Guiding of Model
 
 
3. Control Method
Zero Cross Trigger Method
Output TURN ON or TURN OFF only on zero cross point of sine wave,may avoid surge or EMI/RFI occurring.
Specially suited to control resistive,capacitive and Non-saturated inductive loads
Variable resistance control method
Power output is controlled by the trigger angle of triac with variable resister 250KQ/110VAC,500KQ/220VAC
 
 
4. Application Hints
 
Input
NPN Output NO
Input
NPN Output NO
Input
NPN Output NO
Input
NPN Output NO
Input
NPN Output NO
Input
NPN Output NO
 
 
Type
Standard type
High voltage type
Model
PN-25LA PN-40LA PN-50LA PN-75LA PN-25LAH PN-40LAH PN-50LAH PN-75LAH
Rated load current
25A 40A 50A 75A 25A 40A 50A 75A
Input voltage
4-20mA
Input resistance
Appr.1.2K
Control method
Phase control
Operating voltage
90-250VAC
250-480VAC
Min. black voltage
600VAC
Voltage drop
1.0V/25℃
Max. durated current
275A 410A 550A 820A 275A 410A 550A 820A
Leakage current
𕟭% of full load
Dielectric strength
Over 2.5KVAC/ 1min.
Isolation strength
Over 50M/500VDC
Operating temperature
-20℃~+80℃
Housing Material
Intensive ABS
Weight
105G
 

5. Dimension and connection diagram
 
 
 
 
 
 

 

 